TXUN-HT

TXUN-HT

分  类:其它

品  牌:欧米茄

厂  商:Omega工业测量(中国)

型  号:TXUN-HT

相关行业:

发布时间:2019-12-19 18:12 浏览人数:

最新产品

产品详情
参数
包装
  • HART Protocol Revision Selectable from HART 5 or HART 7
  • RTD, TC, Ω, and Bipolar mV Input
  • 2 Analog Inputs and 5 Device Variables with Status Available
  • Hardware Assessed for Use in SIL Applications
  • Mounting in Hazardous Gas and Dust Area

  • Application
    • Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
    • HART communication and 4 to 20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
    • Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
    • Amplification of bipolar mV signals to standard 4 to 20 mA current signals.
    • Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.
    Technical Characteristics
    •HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
    • The HART 7 protocol offers:
         • Long Tag numbers of up to 32 characters.
         • Enhanced Burst Mode and Event notification with time stamping.
         • Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
         • Process signal trend measurement with logs and summary data.
         • Automatic event notification with time stamps.
         • Command aggregation for higher communication efficiency.
         • TXUN-HT is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
         • Continuous check of vital stored data. Meeting the NAMUR NE 21 recommendations, the TXUN-HT HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the TXUN-HT meets NAMUR NE43 and NE89 recommendations.
    Mounting/Installation
    • For DIN form B sensor head mounting.
    • Configuration via TXUN-KIT for standard set up or via HART programming unit for Hart Communication set up. See links in Notes.

    Specifications
    Environmental Conditions
    Operating Temperature:-40 to 85°C
    Calibration Temperature: 20 to 28°C
    Relative Humidity: < 95% RH (non-cond.)
    Protection Degree (encl./terminal): IP68/IP00
    Mechanical Specifications
    Dimensions: Ø 44 x 20.2 mm
    Weight Approx: 50 g
    Wire Size: 1 x 1.5 mm2 stranded wire
    Screw Terminal Torque: 0.4 Nm
    Vibration:IEC 60068-2-6
    2 to 25 Hz: ±1.6 mm
    25 to 100 Hz: ±4 g
    Common Specifications
    Supply
    Supply Voltage: 8.0 to 30 Vdc
    Isolation Voltage
    Isolation Voltage, Test/Working: 1.5 kVAC/50 Vac
    Response Time
    Response Time (Programmable): 1 to 60 s
    Voltage Drop: 8.0 Vdc
    Programming: Loop Link and HART
    Signal/Noise Ratio: > 60 dB
    Accuracy: Better than 0.05% of selected range
    Signal Dynamics, Input:, 22 bit
    Signal Dynamics, Output: 16 bit
    EMC Immunity Influence: < ±0.1% of span
    Extended EMC immunity: NAMUR NE21, A Criterion, Burst: < ±1% of span
    Input Specifications
    Common Input Specifications
    Max. Offset: 50% of selected max. value
    RTD Input
    RTD Type: Pt50/100/200/500/1000; Ni50/100/120/1000
    Cable Resistance per Wire: 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
    Sensor Current: Nom. 0.2 mA
    TC Input
    Thermocouple Type: B, E, J, K, L, N, R, S, T, U, W3, W5, LR
    Cold junction compensation (CJC): Constant, internal or external via a Pt100 or Ni100 sensor
    Voltage Input
    Measurement Range: -800 to 800 mV
    Min. Measurement Range (Span): 2.5 mV
    Input Resistance: 10 MΩ
    Output Specifications
    Current Output
    Signal Range: 4 to 20 mA
    Min. Signal Range: 16 mA
    Load (@ Current Output): ≤ (Vsupply - 8)/0.023 [Ω]
    Sensor Error Indication: Programmable 3.5 to 23 mA
    NAMUR NE43 Upscale/Downscale: 23 mA/3.5 mA
    Common Output Specifications
    Updating Time: 440 ms
    HART Protocol Revisions: HART 7 and HART 5
    Observed Authority Requirements
    EMC: 2014/30/EU
    EAC: TR-CU 020/2011
    Approvals
    ATEX 2014/34/EU: KEMA 03ATEX1537
    IECEx: KEM 10.0083X
    FM: FM17US0013X
    CSA: 1125003
    INMETRO:NCC 12.0844 X
    EAC Ex TR-CU 012/2011: RU C-DK.GB08.V.00410
    DNV-GL Marine: Stand. f. Certific. No. 2.4
    SIL: Hardware assessed for use in SIL applications


















































































暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!