RD9900 Series

RD9900 Series

分  类:其它

品  牌:欧米茄

厂  商:Omega工业测量(中国)

型  号:RD9900 Series

相关行业:

发布时间:2019-12-19 18:11 浏览人数:

最新产品

产品详情
参数
包装
  • 6 or 12 Point Models Available (12 Point Shown)
  • Clear 5.6" TFT Color LCD Display
  • Large Capacity of Data Memory and Various Recording Method
  • Multi-Points Recording with High-Speed/ Accuracy
  • Easy Operating and Programming without Manuals
  • LAN Network Capability
  • Safety System and Reliability
  • Analyzing/Data Acquisition Application Software

  • RD9900 Series are network compatiblepaperless recorders withhigh performance and highoperating function employed highvisibility 5.6" TFT color LCD. Highspeed of sampling rate 100 ms for12 points and high accuracy of±0.1% were realized, and measureddata is stored into internal memoryand maximum 2 GB compact flashcard. As it can be monitored by aweb browser display on severalcomputers on intranet or internet,FTP transfer of data file and e-mailnotification are also available.The recorder can be used forvarious applications such asdata management, research,development, remote and widerange monitoring by utilizinginternet environment.

    Input SPECIFICATIONS
    Number of Measuring Points:
        RD9906: 6 points
        RD9912: 12 points
    Input Types: Universal (refer to the table of inputs on page S-28, RD200/2800 Series)
    Accuracy Rating:Refer to the table of inputs
    Reference Junction Compensation Accuracy: K, E, J, T, N, Platinel II; ±0.5ºC or less; R, S, NiMo-Ni, CR-AuFe, WRe5-WRe26, W-Wre, U, L; ±1.0ºC or less
    Sampling Rate: Approximately 100 ms for all points
    Burnout: Disconnection of input signal is detected on thermocouple and resistance thermometer input; UP/DOWN disable is selectable for each input
    Scaling: Range/scale is selectable when DC voltage/current is programmed
    Digital Filter: Programming FIR filter for each point (common to all points)
    Allowable Signal Source Resistance:
        Thermocouple Input (Burnout Disable)/DC voltage input (±2 V or less): 1 kOhms or less
        DC Voltage Input (±5 to ±50 V): 100 Ohms or less
        Resistance Thermometer: Per wire 10 O or less (same resistance for 3 wires)
    Input resistance: DC voltage, thermocouple input; approximately 1 MΩ
    Maximum Input Voltage: DC voltage input (±2 V or less)/thermocouple input (burnout disable)
    Dielectric Strength Between Channels: 1000 Vac or more between each channel (high strength semiconductor relay used)

    DISPLAY SPECIFICATIONS
    Display: 5.6" TFT color LCD
    Display Types:
        Measured Data Display: Trend screen, data screen, bar-graph screen
        Historical Trend Display: Simultaneous display with real-time trend is available
        Information Display: Alarm display, marker list, file list
        Setting Screen: Alarm, computation, memory, system, maintenance, communication, etc.
    Trend Screen: 12 colors selectable
        Display Screen: 5 screens (5 groups)
        Display Points: Maximum 44 points/screen/
        Time Axis Direction: Vertical or horizontal
        Line Width: 1/3/5 dot selectable
        Scale Display: 4 scales
        Tag/Data Display: Show/hide selectable Marker Display
    Data screen: Display screen, 5 screens (5 groups)
        Display Points: Maximum 44 points/screen
        Display Contents: Measured value, channel/tag, unit, alarm status
    Bargraph Screen: 12 colors selectable
        Display Screen: 5 screens (5 groups)
        Display Points: Maximum 44 points/screen
        Display Direction: Vertical or horizontal
        Scale Display: 1 scale
    Information Display:
        Alarm Display: Alarm activation/released history display Marker List
        File List: Group data file list display
    LCD Back Light: Auto/manual OFF function
    LCD Brightness: 4 levels adjustment

    RECORDING SPECIFICATIONS
    Internal Memory: Flash memory, 4 MB capacity
    External Memory: CF card, 32 MB to 2 GB capacity; 128 MB CF card is included as standard
    Recording cycle: 100, 200, 500 ms*; 1, 2, 3, 5, 10, 15, 20, 30 s; 1, 2, 3, 5, 10, 15, 20, 30, 60 min
    Numbers of Logging Files: 250/numbers of used groups
    Logging Data: Measured data; file name (group name), time of day, month and year of recording start, tag, measured data, alarm status/types
    Storing Types: Binary/CSV type
    Storing Methods:
        Manual Start/Stop: Dedicated key operation
        Schedule: Designation for time of day and date
        Trigger Signal: Alarm event *Pre-trigger is selectable
    Measuring Numbers of Pre-Trigger: Maximum 950 data
    Recording Cycle*: Up to 3 groups of 12 points/group canbe programmed for 100, 200 and 500ms recording; 5 groupsof 44 points/group for recording with 1s or more (total of100 points programming possible)

    Recording Duration (CF Card):
    When 6 channels recorded in sampling mode (real data)
    Recording Cycle128MB256MB512MB1GB2GB
    0.1 sec6.32 days12.6 days25.3 days50.6 days101 days
    1 sec63.2 days126 days253 days1.4 yrs2.8 yrs
    60 sec10 yrs21 yrs42 yrs83 yrs166 yrs

    When 12 channels recorded in sampling mode (real data)
    Recording Cycle128MB256MB512MB1GB2GB
    0.1 sec3.16 days6.32 days12.6 days25.3 days50.6 days
    1 sec31.6 days63.2 days126 days253 yrs1.4 yrs
    60 sec5.2 yrs10 yrs21 yrs42 yrs83 yrs


    COMPUTATION SPECIFICATIONS
    Computation Points: Maximum 44 points
    Computation Types:
        Arithmetic Operations: Addition, subtraction, multiplication, division, remainder, exponential
        Comparison Operations: Equality, inequality, great, less, equality/great, equality/less
        Logical Operations: AND, OR, XOR, NOT
        General Functions: Round-up, round-down, absolute value, square root, exponent of e, natural logarithm, common logarithm
        Integration Operations: Analog integration, digital integration
        Channel Data Operations: Measured data computation, calculated data computation

    ALARMSPECIFICATIONS
    Setups: Up to 4 alarms can be programmed per channel
    Alarm Types: Upper limit, lower limit, differential higher limit, differential lower limit (deadband is selectable), abnormal data
    Delay Function: Setup range of alarm delay, 1 to 3600 sec
    Alarm Settings: AND/OR selectable

    Communication Functions Network
    FTP Server: Data file can be read from the network computer
    Web Server: Conformed to HTTP1.0; displays the alarm,information of maintenance by browser software (InternetExplorer 5.0 or later, Net Scape 6.0 or later, Opera 7 or later)* User’s ID and password registration available
    E-Mail: E-Mail notification at specified time for alarmactivation; report data at specified time is selectable fromall registered

    USB COMMUNICATIONS
    USB: Communication type, USB1.1
    Transfer Systems: Bulk transfer, control transferCommunication Contents: File transfer by virtual driveconnection
    GENERAL SPECIFICATIONS
    Rated Power Voltage: 100 to 240 Vac (universal power supply); 50/60 Hz
    Maximum Power Consumption: 50 VA (DO: all points ON, 240 Vac)
    Reference Operating Condition:
        Ambient Temperature/Humidity Range: 21 to 25°C, 45 to 65% RH
        Power Voltage: 100 Vac, ±1.0%
        Power Frequency: 50/60 Hz ±0.5%
        Attitude: Left/right 0°, forward/backward 0°
        Warm-Up Time: Longer than 30 minutes
    Normal Operating Condition:
        Ambient Temperature/Humidity Range: 0 to 50°C, 20 to 80% RH
        Power Voltage: 90 to 264 Vac
        Power Frequency: 50/60 Hz ±2%
        Attitude: Left/right 0°, forward tilting 0°, backward tilting 0° to 20°
    Transportation Condition (At the Packed Condition on Shipment from Our Factory):
        Ambient Temperature/Humidity Range: -20 to 60°C, 5 to 90% RH (note: no dew condensation)
        Vibration: 10 to 60 Hz, 0.5 G (4.9 m/S2) or less
        Impact: 40 G (392 m/ S2) or less
    Storage Condition: Ambient temperature/humidity range -20 to 60°C, 5 to 90%RH (note: no dew condensation)
    Power Failure Protection: Setups and data are backed up by flash memory
    Clock: Lithium battery backs up RAM (minimum 5 years)
    Insulation Resistance:
        Secondary Terminals and Protective Conductor Terminals: 20 MΩ or more at 500 Vdc
        Primary Terminals and Protective Conductor Terminals: 20 MΩ or more at 500 Vdc
        Primary and Secondary Terminals: 20 MΩ or more at 500 Vdc
    Dielectric Strength:
        Secondary Terminals and Protective Conductor Terminals: 1 minute at 500 Vac
        Primary Terminals and Protective Conductor Terminals: 1 minute at 1500 Vac
        Primary and Secondary Terminals: 1 minute at 2300 Vac
    Case Assembly Material:
        Door Frame: ABS resin
        Case: Steel
    Color:
        Door Frame: Black (equivalent to Mussel N3.0)
        Case: Painting color, gray (equivalent to Mussel N7.0)
    Weight: 2.2 kg (4.85 lbs)
    Mounting: Panel mounting

    OPTIONS SPECIFICATIONS
    NameContents
    Alarm OutputRelay contact ouput at alarm activation and abnormal input; output points: 12; contact capacity: mechanical relay, 100 Vac 0.5 A, 240 Vac 0.2 A
    Communication InterfaceCommunication interface for high-order instruments RS232C/RS485 switchable
    *Ethernet and USB equipped as standard

    Terminal Screws:
        Power Terminals/Protective Conductor Terminals/Communications Terminals: M4.0
        Measuring Input Terminals/Alarm Output Terminals/Remote Contact Terminals: M3.5





















暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!