The OM-CP-HITEMP140X2-TD series of dual probe data loggers offer extreme flexibility for high temperature monitoring applications. These models all feature a 5.1 cm (2") rigid transitional diameter probe to measure ambient temperature, combined with a second bendable or flexible probe option. The rigid ambient probe is made of stainless steel, offers a fast response time and is suitable for the harshest environments.
The OM-CP-HITEMP140X2-TD-PT-1 and theOM-CP-HITEMP140X2-TD-PT-5 models combine the 5.1 cm (2") rigid ambient probe with a 61 cm (24") bendable probe made of stainless steel with either a 2.5 cm (1") or 12.7 cm (5") probe sheath at the tip. The stainless steel PT probe options provide the ability to retain shape when bent into position and offer an extremely high measurement range of up to 350°C.
The OM-CP-HITEMP140X2-TD-FP-72 combines the 5.1 cm (2") rigid ambient probe with a 183 cm (72") long lightweight RTD flexible probe, designed for easy placement. The flexible probe option is very pliable and coated with PFA insulation making it ideal for use inside small vials and test tubes. This probe style has a narrow diameter, high accuracy and is ideal for steam sterilization and lyophilization. The flexible probe is also compatible with the OM-CP-MICRODISC probe attachment, used for the surface temperature monitoring of shelving and more.
The operating temperature range for the data logger body is -40 to 140°C (-40 to 284°F). Because of the simultaneous ambient and remote temperature recording, the OM-CP-HITEMP140X2-TD series is ideal for use in autoclave mapping, food processing applications, and much more.
The OM-CP-HITEMP140X2-TD series utilizes the latest software. This allows for simple starting, stopping and downloading of collected data. The devices are able to store up to 32,700 time and date stamped readings in non-volatile solid state memory. Once the readings have been downloaded to the software, it can be viewed in graphic, tabular, and summary form for easy analysis, as well as the potential to be exported into Excel for further calculations.
The OM-CP-MULTIMOUNT-Z is a versatile mount or stand for use with the OM-CP-HITEMP140 series of data loggers. It can be used to stabilize a logger inside an autoclave, or screwed to a flat surface to create an anchored base. Made of 316 stainless steel, theOM-CP-MULTIMOUNT-Z is able to withstand temperatures up to 150°C (302°F) making it ideal for use in autoclave sterilization processes.
SPECIFICATIONS
TEMPERATURE
Temperature Sensor:
OM-CP-HITEMP140X2-TD-PT-1,
OM-CP-HITEMP140X2-TD-PT-5: Rigid ambient RTD probewith a stainless steel bendable RTD probe
OM-CP-HITEMP140X2-TD-FP-72: Rigid ambient RTD probewith a PFA insulated flexible RTD probe
Probe Measurement Range:
Rigid Ambient Probe: -200 to 260°C (-328 to 500°F)
Stainless Steel Bendable Probe: -200 to 350°C(-328 to 662°F)
Flexible Probe: -60 to 260°C (-76 to 500°F)
Temperature Resolution: 0.01°C (0.02°F)
Calibrated Accuracy: ±0.1°C (±0.18°F)
GENERAL
Reading Rate: 1 reading every second up to1 reading every 24 hours
Memory: 32,767 readings
Start Modes:
• Software programmable immediate start
• Delay start up to 18 months in advance
Stop Modes: Manual or Timed (specific date and time)
Real Time Recording: May be used with PC to monitor andrecord data in real time
Password Protection: An optional password may beprogrammed into the device to restrict access to configurationoptions. Data may be read out without the password
Readings in Trigger Settings Mode: 16,383 readings
Trigger Settings: High and Low limits may be set. Once datameets or exceed set limits, the device will record to memory.Bi-level start and stop triggers can also be programmed. Userscan specify the number of readings to take after the devicetriggers. (Triggering on channel 1 only)
Memory Wrap Around: Yes (software selectable)
Battery Type: 3.6V high-temperature lithium battery included;user replaceable
Battery Life: 1 year typical [1 minute reading rate at 25°C (77°F)]
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Data Format: Date and time stamped °C, °F, °R, K
Time Accuracy: 1 minute/month at 25°C (77°F)
Computer Interface: OM-CP-IFC400 USB docking station orOM-CP-IFC406 multiplexer interface required; 125,000 baud
Software: Windows XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -40 to 140°C (-40 to 284°F),0 to 100% RH, 0.002 to 100 psia
IP Rating: IP68
Dimensions (Body): 48 H x 24.6 mm dia (1.89 x 0.97")
Dimensions (Probe):
Rigid Ambient Probe (All Models): 51 L x 3.2 mm dia(4.8 mm transitional dia);
2.0 x 0.125" (0.188" transitional dia)
OM-CP-HITEMP140X2-TD-PT-1
Stainless Steel Bendable Probe:
Probe Tip: 42 L x 3.2 mm dia (1.7 x 0.125")
Bendable Portion: 559 L x 1.6 mm dia (22 x 0.062")
OM-CP-HITEMP140X2-TD-PT-5
Stainless Steel Bendable Probe:
Probe Tip: 121 L x 3.2 mm dia (4.8 x 0.125") with25 L x 4.8 mm dia (1 x 0.188") handle
Bendable Portion: 559 L x 1.6 mm dia (22 x 0.062")
OM-CP-HITEMP140X2-TD-FP-72 Flexible Probe: 1829 L x 2.5 mm dia (72 x 0.1")
Weight:
OM-CP-HITEMP140X2-TD-PT: 85 g (3.0 oz)
OM-CP-HITEMP140X2-TD-FP: 100 g (3.5 oz)
Materials:
Body: 316 stainless steel, PEEK
Bendable Probe: 316 stainless steel
Flexible Probe: PFA insulated cable
暂无内容提供
暂无内容提供