The OM-CP-HITEMP140X2-FP Series of dual channelhigh temperature data loggers feature a stainless steeldata logger body and are available with either two 183cm (72") flexible probes (OM-CP-HITEMP140X2-FP-72)or with one flexible probe and a stainless steel bendableprobe combination (OM-CP-HITEMP140X2-FP-72-PT-1and OM-CP-HITEMP140X2-FP-72-PT-5).

The dual probes of the OM-CP-HITEMP140X2-FPSeries allow for simultaneous temperature monitoringand provide flexibility in applications such as ovenmapping, surface temperature monitoring, autoclavevalidation and sterilization processes.

The OM-CP-HITEMP140X2-FP-72 model offers two183 cm (72") long, lightweight, flexible RTD probescoated with PFA insulation. The FP probe designallows the probe to be easily maneuvered and is idealfor temperature monitoring inside test tubes, small vials,and other delicate applications. The narrow thermistorprobe tip is compatible for use with theOM-CP-MICRODISC probe attachment allowing forprecise surface temperature monitoring of shelvingand more.

The OM-CP-HITEMP140X2-FP-72-PT-1 andOM-CP-HITEMP140X2-FP-72-PT-5 models feature a61 cm (24") stainless steel bendable probe with theoption of either a 2.5 cm (1") or 12.7 cm (5") probe tip(sheath). The stainless steel probe can be bent, angled,and coiled in any direction and formed into position asneeded. The sharp probe tip allows for easy insertionand has an extended measurement range of-200 to 350°C (-328 to 662°F).

The body of the OM-CP-HITEMP140X2-FP dataloggers are capable of operating in temperatures from-40 to 140°C (-40 to 284°F). All models have thecapacity to store up to 32,700 time and date stampedreadings and feature non-volatile solid state memorythat will retain data even if the battery becomesdischarged.

The OM-CP-HITEMP140X2-FP utilizes the latestsoftware. The device can be started, stopped, and datacan be downloaded quickly and easily. Once in thesoftware, the data can be reviewed in graphic, tabular,or summary form as well as exported to Excel® forfurther analysis and calculations.

SPECIFICATIONS
TEMPERATURE
Temperature Sensor:
    OM-CP-HITEMP140X2-FP: Flexible RTD probe
    OM-CP-HITEMP140X2-FP-PT: Flexible RTD Probe andbendable RTD probe
Probe Measurement Range:
    Flexible Probe: -60 to 260°C (-76 to 500°F)
    Bendable Probe: -200 to 350°C (-328 to 662°F)
Temperature Resolution: 0.01°C (0.02°F)
Calibrated Accuracy: ±0.1°C (±0.18°F)

GENERAL
Reading Rate: 1 reading every second up to 1 reading every24 hours
Memory: 32,767 readings
Start Modes:
     Software programmable immediate start
     Delay start up to 18 months in advance
Stop Modes: Manual or Timed (specific date and time)
Real Time Recording: May be used with PC to monitor andrecord data in real time
Password Protection: An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password
Readings in Trigger Settings Mode: 16,383 readings
Trigger Settings: High and Low limits may be set. Once data meets or exceed set limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the devicetriggers. (Triggering on channel 1 only)
Memory Wrap Around: Yes (software selectable)
Battery Type: 3.6V high-temperature lithium battery included;user replaceable
Battery Life: 1 year typical [1 minute reading rate at 25°C (77°F)]
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Data Format: Date and time stamped °C, °F, °R, K
Time Accuracy: 1 minute/month @ 25°C (77°F)
Computer Interface: OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud
Software: Windows XP SP3/Vista/7 and 8 (32- and 64-bit)
Operating Environment: -40 to 140°C (-40 to 284°F), 0 to 100% RH, 0.002 to 100 psia
IP Rating: IP68
Dimensions (Body): 48 H x 24.6 mm dia (1.89 x 0.97")
Dimensions (Probe):
    OM-CP-HITEMP140X2-FP-72:
      Flexible Probe: 1829 L x 2.5 mm dia (72 x 0.1")
    OM-CP-HITEMP140X2-FP-72-PT-1 with 2.5 cm (1")
      Bendable Probe:
      Probe Tip: 42 L x 3.2 mm dia (1.7 x 0.125")
      Bendable Portion: 559 L x 1.6 mm dia (22 x 0.062")

    OM-CP-HITEMP140X2-FP-72-PT-5 with 12.7 cm (5")
      Bendable Probe:
      Probe Tip: 121 L x 3.2 mm dia (4.8 x 0.125") with 25 L x 4.8 mm dia (1 x 0.188") handle
      Bendable Portion: 559 L x 1.6 mm dia (22 x 0.062")
Weight:
    OM-CP-HITEMP140X2-FP-72: 115 g (4.1 oz)
    OM-CP-HITEMP140X2-FP-72-PT: 110 g (3.9 oz)
Materials:
    Body: 316 stainless steel, PEEK
    Bendable Probe: 316 stainless steel
    Flexible Probe: PFA insulated cable

















暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!