OM-CP-HITEMP140-FR

OM-CP-HITEMP140-FR

分  类:其它

品  牌:欧米茄

厂  商:Omega工业测量(中国)

型  号:OM-CP-HITEMP140-FR

相关行业:

发布时间:2019-12-19 18:05 浏览人数:

最新产品

产品详情
参数
包装

The OM-CP-HITEMP140-FR is a high temperaturedata logger with an ultra-fast response time to recordtemperature during rapidly changing thermal processes.This high temperature data logger features a50 L x 1.59 mm dia (2 x 0.0625") probe and is capableof recording up to 4 Hz, which is 4 times faster thanother data loggers in this class. This allows thetemperature sensor to quickly adapt and accuratelyrecord temperature variations in changing environments.Applications include oven profiling, steam sterilization,autoclave verification and mapping, seafood processing,flash freezing and more.

The OM-CP-HITEMP140-FR data logger is designedwith food grade stainless steel. The device can beplaced in environments up to 140°C (284°F) and theprobe is capable of measuring from -200 to 260°C (-328to 500°F). The OM-CP-HITEMP140-FR is also availablewith an optional thermal shield enclosure to extend theoperating range of the data logger to -200 to 250°C(-328 to 482°F). The OM-CP-HITEMP140-FR-TSK(Thermal Shield Kit) comes with either a vented orflush top enclosure to accommodate a multitude ofapplications.

The Trigger Settings feature of theOM-CP-HITEMP140-FR allows users to configurehigh and low temperature thresholds that when met orexceeded, will automatically start or stop recording datato memory. This data logger is capable of storing up to32,700 date and time stamped readings and features anonvolatile solid state memory which retains data even ifthe battery becomes discharged.

The OM-CP-MULTIMOUNT-Z is a versatile mount orstand for use with the OM-CP-HITEMP140 series ofdata loggers. It can be used to stabilize a logger insidean autoclave, or screwed to a flat surface to create ananchored base. Made of 316 stainless steel, theOM-CP-MULTIMOUNT-Z is able to withstandtemperatures up to 150°C (302°F) making it ideal foruse in autoclave sterilization processes.

The OM-CP-HITEMP140-FR utilizes the latestsoftware. Data can be viewed in graphical or tabularformats and summary and statistics views are availablefor further analysis. The software features export toExcel®, data annotation, digital calibration and more.

SPECIFICATIONS
OM-CP-HITEMP140-FR
(DATA LOGGER WITHOUT THERMAL SHIELD)
TEMPERATURE
Temperature Sensor: 100 Ω platinum RTD
Probe Measurement Range: -200 to 260°C (-328 to 500°F)
Temperature Resolution: 0.01°C (0.02°F)
Calibrated Accuracy: ±0.1°C (±0.18°F) 20 to 140°C (68 to 284°F)

GENERAL
Data Logger Response Time (Hours: Minutes: Seconds: Fractions of a Second):
    In Air:
t60 - 00:00:39:00 (39 sec to reach 60% of stepchange)
t90 - 00:02:71:00 (2 min 71 sec to reach 90% of step change)
    In Water:
t60 - 00:00:10:00 (10 sec to reach 60% of step change)
t90 - 00:00:12:00 (12 sec to reach 90% of step change)
Reading Rate: 4 readings per second up to 1 reading every 24 hours
Memory: 32,767 readings
Start Modes:
     Software programmable immediate start
     Delay start up to 18 months in advance
Stop Modes: Manual or timed (specific date and time)
Trigger Settings: High and low limits may be set. Once datameets or exceed sets limits, the device will record to memory.Bi-level start and stop triggers can also be programmed.Users can specify the number of readings to take after thedevice triggers
Readings in Trigger Settings Mode: 10,922 readings
Real Time Recording: May be used with PC to monitor and record data in real time
Password Protection: An optional password may be programmed into the device to restrict access to configuration options. Data may be read without the password
Memory Wrap Around: Yes
Battery Type: 3.6V high-temperature lithium battery included; user replaceable
Battery Life: 2 years typical (1 minute reading rate)
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Data Format: Date and time stamped °C, °F, °R, K
Time Accuracy: ±1 minute/month at 25°C (77°F)
Extended Operation: ±20 minutes/month at 140°C (284°F)
Computer Interface: OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud
Software: Windows® XP, SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -40 to 140°C (-40 to 284°F), 0 to 100% RH, 0.002 to 100 PSIA
IP Rating: IP68
Dimensions (Body): 48 H x 24.6 mm D (1.89 x 0.970")
Dimensions (Probe): 44.5 L x 1.59 mm dia (1.75 x 0.0625"); 4.78 mm transitional dia (0.188")
Weight: 65 g (2.3 oz)
Materials: 316 Stainless Steel, PEEK





暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!