  • Calibrate Thermocouple Instruments to 0.1 and 0.01, °F and °C
    Types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), (T-DIN) and P (Platinel): -13.000 to 80.000 mV
  • Calibrate RTD Instruments to 0.1 and 0.01, °F and °C
    Pt 10, 50, 100, 200, 500 and 1000 (3850)
    Pt 100 (alpha = 3902, 3916, 3926)
    Cu 10 and 50 and Ni 120
  • Calibrate with Confidence
    Resolution to 0.01, °F and °C; Accurate to 0.2°
    Cold Junction Sensor Accurate to 0.05°C
    NIST Traceable Cold Junction Sensor in Isothermal Block
  • Troubleshoot RTD Sensors and Instruments
    Automatic Detection of 2-, 3- or 4-Wire Connections Indicates When Individual Wire Connections are Open
    Verify Proper Instrument Operation by Measuring the Excitation Current
  • Fast Easy Calibrations
    Instantly Select 3 Outputs with the EZ-CHECK Switch
    Easily Find Trip Points with 2 Speed EZ-DIAL Knob and Automatic Stepping
  • Verify Resistance, Cold Junction Temperature and Output
    Secondary Display of Resistance for RTDs and Compensated millivolt Setting, and Cold Junction Temperature for Thermocouple
  • Use in the Plant, Field or Shop
    Includes Rubber Boot and mV Test Leads
    Low Profile Switches Resist Accidental Damage
    Brass Screws for Thermocouple Wires Plus Miniature Thermocouple Socket
  • Perform Heat Treating Surveys and Accuracy Tests
    Meets or Exceeds the Requirement of AMS 2750 as Both a Secondary Standard Instrument and as a Field Test Instrument
  • NIST Cert (No Points)

  • THERMOCOUPLE CONNECTIONS
    Simulating or readingthermocouples requiresthe use of thermocoupleor extension gradethermocouple wire.Plug thermocouple wires intothe miniature thermocouplejack or place barethermocouple wiresonto the brass block underthe screws.

    The CL543B has two bananajacks (1+ and 2-) mounted inthe top end of the housing.These are not temperaturecompensated and are to beused only for millivolt signals.

    RTD CONNECTIONS
    Simulating or reading RTDsuses copper wire. Plug 2-, 3- or4-wires into the correspondingjacks on the calibrator. For RTDsource the CL543B simulates the(+) RTD from jacks 1 and 4 andthe (-) RTD from jacks 2 and 3.When reading an RTD sensorthe CL543B uses patentedcircuitry to automatically detectsif 2-, 3- or 4-wires are connected.This is helpful to troubleshootsensor connections.

    Specifications
    Operating Temperature Range:-20 to 60°C (-5 to 140°F)
    Storage Temperature Range:-30 to 60°C (-22 to 140°F)
    Temperature Effect: ≤±25 ppm/°C ofrange
    Cold Junction Sensor: ≤±0.01% °/°from ambient temperature (°C or °F)
    Relative Humidity Range:
        10% ≤RH ≤90% (0 to 35°C), non-condensing
        10% ≤RH ≤70% (35 to 60°C), non-condensing
    Normal Mode Rejection: 50/60 Hz, 50 dB
    Common Mode Rejection: 50/60 Hz, 120 dB
    Dimensions: 143 L x 76 W x 41 mmH (5.63 x 3 x 1.60")
    Weight: 0.34 kg (12.1 oz) with bootand batteries
    Batteries: Four “AA” alkaline 1.5V(LR6) (included), optional NiMhrechargeable battery kit [120 Vac(North America only); charger,4 NiMh batteries, AC and DC cords
    Battery Life: 50 hours, low batteryindication with nominal 1 hour ofoperation left
    Over-Voltage Protection: Up to60 vrms (rated for 30 seconds),protection against misconnection
    Alerts: Red LED displaysOVERLOAD or out of range conditions
    Display: High contrast graphic liquidcrystal display, LED backlighting foruse in low lit areas
    Voltage Source
    Ranges and Resolution:-13.000 to 80.000 mV and -13.0000to 80.0000 mV
    Accuracy: ±(0.008% of setting +0.006 mV)
    Source Current: ≥10 mA
    Output Impedance: <0.3Ω
    RMS Noise: ≤±0.0005 mV from0.1 to 10 Hz
    Short Circuit Duration: InfiniteVoltage Read
    Ranges and Resolution:-13.000 to 80.000 mV and -13.0000to 80.0000 mV
    Accuracy: ±(0.008% of reading +0.006 mV)
    Input resistance: ≥10 MΩThermocouple Source
    Accuracy: ±(0.008% of setting +0.006 mV)
    Cold Junction Compensation:±0.05°C (±0.09°F); thermistortraceable to NIST for 11 years
    Output Impedance: <0.3Ω
    Source Current: >10 mA (drives80 mV into 10Ω)
    RMS Noise: ≤±0.0005 mV from0.1 to 10 Hz
    Thermocouple Read
    Accuracy: ±(0.008% of reading +0.006 mV)
    Cold Junction Compensation:±0.09°F (±0.05°C); thermistortraceable to NIST for 11 years
    Input Impedance: >10 MΩ
    Open Thermocouple Threshold:10,000Ω nominal
    Pulse: <10 microamp pulse for300 milliseconds
    RTD and O Source
    3- and 4-Wire Accuracy:
        From 1 to 10.2 mA ExternalExcitation Current: ±(0.015% of setting + 0.05Ω)
        Below 1 mA of External Excitation Current:Add (0.025 mV/mA excitationcurrent)
    2-Wire Accuracy: Add 0.1Ω to 3-wireand 4-wire accuracy
    Resistance Ranges:
        400Ω Range: 0.00 to 401.00 and0.000 to 401.000
        4000Ω Range: 0.0 to 4010.0 and0.00 to 4010.00
    RMS Noise:
        400Ω Range: ≤±0.005Ω from0.1 to 10 Hz
        4000Ω Range: ≤±0.05Ω from0.1 to 10 Hz
    Allowable Excitation Current Range:
        400Ω Range: 10.2 mA max; steadyor pulsed/intermittent
        4000Ω Range: 1 mA max; steadyor pulsed/intermittent
    Pulsed Excitation CurrentCompatibility: DC to 0.01 secondpulse width, 0.025 mV, mA excitationcurrent
    RTD and Ohms Read
    Resistance Ranges:
        400Ω Range: 0.00 to 401.00 and0.000 to 401.000
        4000Ω Range: 0.0 to 4010.0 and0.00 to 4010.00
    Accuracy: ±(0.015% of reading +0.05Ω)
    Excitation Current: 0.9 mA to 401Ω,0.4 mA to 4010Ω (nominal)


































暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!