  • Large Auto-Sensing Backlit Display
  • “Dial-Style” Digital Bar Graph
  • Intuitive and “User-Friendly” Interface
  • Optional Field Upgradable Relays
  • Warning LED Indicator
  • Custom 13-Character Label Capabilities
  • Factory Reset Capability

  • The DPU91 transmitter provides asingle channel interface for manydifferent parameters including flow,pH/ORP, conductivity/resistivity,salinity and temperature. TheDPU91-BC transmitter has theadded capability of supporting thebatch module for batching control.The extra-large (3.90 x 3.90")autosensing backlit display canbe viewed at 4 to 5 times thedistance over traditional transmitters.The highly illuminated display andlarge characters reduce the risk ofmisreading or misinterpreting thedisplayed values. The display showsseparate lines for units, main andsecondary measurements as wellas a “dial-style” digital bar graph.The DPU91 is offered in both panelor field-mount versions. Bothconfigurations can run on 12 to32 Vdc power (24 Vdc nominal)and have 4 to 20 mA outputs.Designed for complete flexibility,plug-in modules allow the unit toeasily adapt to meet changingcustomer needs. Optional modulesinclude relay, direct conductivity/resistivity, batch and a PCcommunications configuration tool.The unit can be used with defaultvalues for quick and easyprogramming or can be customizedwith labeling, adjustable minimumand maximum dial settings, and unitand decimal measurement choices.

    Specifications
    General
    Input Channels: 1
    Input Types: Digital serial ASCII, TTL level, 9600 bps
    Frequency Range: 0.5 to 1500 Hz
    Accuracy: 0.5% of reading (display)
    Measurement Types: Flow, pH/ORP, conductivity/resistivity, salinity, pressure, temperature or batch
    Enclosure and Display
    Case Material: PBT
    Window: Shatter-resistant glass
    Keypad: 4 buttons, injection-molded silicone rubber seal
    Display: Backlit, 7 and 14-segment
    Update Rate: 1 second
    LCD Contrast: 5 settings
    Indicators: “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
    Enclosure: ¼ DIN, NEMA 4X/IP65
    Mounting Panel: ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket (included)
    Field Mounts: Specified to OMEGA™ field mount junction boxes
    Weight: 0.63 kg (1.63 lb) DPU91-FLOW Series
    Display Ranges For conductivity/resistivity version visit omega.com/dpu91_conductivity For pH/ORP version visit omega.com/ dpu91_ph
    Flow Rate: -9999 to 99999 units per second, minute, hour or day
    Totalizer: 0.00 to 99999999 units (program lockout or resettable)
    Temperature: -99 to 350°C (-146 to 662°F)
    Volume: 0 to 99999 cm³, m³, in³, ft³, gal, L, lb, kg, %
    Environmental
    Ambient Operating Temperature:
        Backlit LCD: -10 to 70°C (14 to 158°F)
        Storage Temperature: -15 to 70°C (5 to 158°F)
    Relative Humidity: 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount
    Maximum Altitude: 4000 m (13,123')
    Electrical Requirements
    Power to Sensors:
        Voltage: 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
        Terminal Blocks: Pluggable screw type 14 AWG maximum wire gauge
    Input Power
    DC: 10.8 to 35.2 Vdc, regulated
    Current Output:
    4 to 20 mA (10.8 to 35.2 VDC, 30 mA max)
    DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc
    DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc
    Open Collector: 1
    Overvoltage Protection: 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
    Relay Specifications (DPU90-R optional)
    Type: SPDT, Form C
    Maximum Current Rating: 5 A resistive 50 mA DC
    Maximum Voltage Rating: 30 Vdc or 250 Vac
    Hysteresis Adjustable: Absolute in engineering units (EUs)
    Latch Reset: In test screen only
    Delay: 9999.9 seconds (maximum)
    Test Mode: Set on/off
    Cycle Time: 99999 seconds (maximum)
    Maximum Pulse Rate: 400 pulses/minute
    Proportional Pulse: 400 pulses/minute
    Volumetric Pulse Width: 0.1 to 3200 s
    Pulse Width Modulation: 0.1 to 320 s
    Input Types
    Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics (For pH models see omega.com/ dpu91_ph)
    Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850 (For conductivity/resistivity models see omega.com/ dpu91_conductivity)
    Input Specifications
    Digital Serial: ACSII, TTL level, 9600 bps
    Frequency Input:
        Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency
        Span: 0.5 Hz to 1500 Hz @ TTL level input
    Accuracy: ± 0.5% or reading maximum error @ 25°C (77°F)
    Repeatability: ±0.2% of reading
暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!