FHG-1112

FHG-1112

分  类:其它

品  牌:欧米茄

厂  商:Omega工业测量(中国)

型  号:FHG-1112

相关行业:

发布时间:2019-12-19 17:35 浏览人数:

最新产品

产品详情
参数
包装
  • Pulsation-Free Measurement
  • Lowest Pressure Loss for High Viscosity
  • Short Response Time
  • Up to 1,000,000 Centistoke Viscosity
  • High Accuracy and Wide Ranges

  • FHG-1000 flow meters measure the flow rate basedon the screw pump principle. A pair of rotors fittedprecisely into the housing constitutes the measuringelement. An integrated gear and non-contact signalpick-up system detects the rotations of the measuringelement and converts them to digital pulses. Togetherwith the housing walls, the rotor edges form closedmeasuring chambers in which the fluid is transportedfrom the inlet to the outlet side. The fluid volume putthrough within one main rotor rotation is the rotationvolume, which is divided by the sensing gear anddigitized, processed and output in the sensor module.

    Sensor System Explanation
    The non-contact pick-up system consists of twoGMR-bridges (sin/cos), which are located in a sensorunit in cartridge design. It detects the movement ofthe sensing gear and routes the sin/cos-signals to thepreamplifier electronics. The preamplifier electronicsdigitize and amplify the sensor signals and multiplythem by a high-resolution interpolator using adjustablesettings. The square wave signals are bidirectional andcan be utilized by any evaluating instrument as well ascomputers and PLC-controls. The resolution isselectable in steps from factor 1 to 128. In case of an1-channel evaluation, a separate directional signal isavailable. An adjustable pulse filter can offset andsuppress negative flows (e.g. generated byvibrations) while still in the device. The frequency of theoutput signals is proportional to the flow (volume flow)and depends on the respective flow meter size. Thefrequency range is from 0 to 100 kHz. The preamplifieris protected against reverse polarity and incorrectconnection. It is suitable for fluid temperatures of-30 to 120°C (-22 to 248°F) and is mounted directly onthe flow meter.

    Flow meter Selection
    For the trouble-free, safe and reliable operation of theflow meters, selecting the correct type and size iscritical. Because of the wide variety of applicationsand flow meter designs, the technical data in thespecifications are of a general nature. Certainproperties of the devices depend on type, size,and measurement range as well as the liquid tobe measured. Please contact the Omega FlowDepartment for detailed information about theappropriate flow meter for your particular application.

    Electronics
    A special sensor system detects any movement of thepair of rotors or of the liquid column. For this purpose,a precision gear connected to a shaft of the rotor pairis scanned by a special magneto-resistive sensor. Thescanning sensor includes two GMR-bridges (sin/cos)and is housed in a removable stainless steel cartridgecase together with a signal conditioning and amplifierunit. The downstream electronics unit features a highresolutionsin/cos-interpolator, which is adjustable with10 different resolution factors. Furthermore, aprogrammable signal filter is available as well, whichcan offset unwanted negative pulse sequences up toan adjustable degree. In addition, a signal for aseparate direction detection, e.g. in case of a1-channel evaluation, is provided by the electronics.Optionally, this output can be used for the detection ofexcess flows and temperatures.

    Specifications
    Frequency Range: 0 to 100 kHz, adjustable
    Measurement Accuracy: ±0.5% of measured value with viscosity of > 21 cSt
    Repeatability Accuracy: ±0.05% with same operating conditions
    Materials
    Gray Cast Iron Model: EN-GJS-400-15 (EN 1563)/16 Mn Cr 5
    Stainless Steel Model: Stainless steel 1.4305/1.4112, others available upon request
    Bearing Fluid: Dependent as anti-friction bearing or SSIC/ wolfram carbide friction bearing
    Seal:
        Standard: FPM
        Optional: PTFE, NBR or EPDM
    Fluid Temperature: -30 to 120°C (-22 to 248°F)
    Viscosity Range: 1 to 1.000.000 cSt
    Installation Position: Any
    Supply Voltage: 10 to 28 Vdc
    Current Consumption: 65 mA at 24 Vdc unloaded
    Delay: < 8 µs
    Protection Class: IP65
    Power Supply
    Supply Voltage: u = 10 to 28 Vdc; reverse pole protection
    Current Consumption: I0 = 65 mA (at 24 Vdc); unloaded
    Delay: tV = 8 µs maximum (between scanning and measured value)
    Signal Outputs
    Output Signal Shape: Quadrature signals (A, B with 90° phase shift)
    Directional Output: Positive high (24V), negative low (0.8 to 1V)
    Error Output: Active high (24V), inactive low (0.8 to 1V)
    Maximum Output Frequency: 100 kHz
    Signal Voltage Output: VSS = 9 to 27 Vdc (channel 1, channel 2, error/direction)
    Signal Output: Current Iout = 300 mA maximum at 24 Vdc (channel 1, channel 2)







































暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!