  • Digital and Analog Modes Operate Simultaneously
  • Programmable Flow Configurations
  • RS485 Standard, Multi-Drop Capability of Up to 256 units
  • Stores Calibration Data for Up to 10 Gases
  • Totalizer Indicates Total Gas Quantity
  • Alarm Limits for High and Low Gas Flow
  • Conversion Factors for Up to 256 Gases
  • Autotune Function for Optimum Control Response
  • Self Diagnostic Tests

  • Microprocessor driven digital flow controllers allow one to program, record, and analyze flow rates ofvarious gases with a computer via an RS485 interface (optional RS232 is available). Controllers can be programmed for various control functions including flow setpoint, totalizer, stop totalizer, read totalizer, totalizer from preset flow, stop at preset total, auto zero, and more.

    Principles of Operation
    Metered gases are divided into two laminar flow paths, one through the primary flow conduit, and the other through a capillary sensor tube. Both flow conduits are designed to ensure laminar flows and, therefore, the ratio of their flow rates is constant. Two precision temperature sensing windings onthe sensor tube are heated, and when flow takes place, gas carries heat from the upstream to thedownstream windings. The resultant temperature differential is proportional to the change inresistance of the sensor windings. A Wheatstone bridge design is used to monitor the temperaturedependent resistance gradient on the sensor windings which is linearly proportional to the instantaneousrate of flow. The output of the Wheatstone bridge is converted to digital format with a 12 Bit ADC(analog to digital converter). An on-board microprocessor and nonvolatile memory store all calibration factors and directly control a proportional electromagnetic valve. The digital closed loop control system continuously compares the mass flow output with the selected flow rate. Deviations from the setpoint are corrected by compensating valve adjustments, with PID algorithm thus maintaining the desired flow parameters with a high degree of accuracy. Output signals of 0 to 5 Vdc or 4 to 20 mA are generated indicating mass molecular based flow rates of the metered gas.

    Interface
    The digital interface operates via RS485 (optional RS232) and provides access to applicable internal data including FLOW SETPOINT, ACTUAL FLOW, ZERO ADJUSTMENTS, and LINEARIZATION TABLE ADJUSTMENTS. The analog interface provides 0 to 5 Vdc, 0 to 10 Vdc and 4 to 20 mA inputs and outputs.

    Auto Zero
    The FMA6500 automatically nulls the sensor zero offset whenever the flow setpoint is below 2% of fullscale. To accommodate this feature the control valve must fully close under that condition. Provisions are made to either disable, force or store the current auto zero via digital commands.

    Totalizer
    The firmware for the FMA6500 provides functions to register total gas quantity. The total mass of gas iscalculated by integrating the actual gas flow rate with respect to time. Digital interface commands areprovided to: SET the totalizer to ZERO; START /STOP totalizing the flow; READ the totalizer; START the totalizer at a preset flow STOP the flow at a preset total.

    Multi-Gas Calibration
    The FMA6500 is capable of storing primary calibration data for up to 10 gases. This feature allows the same FMA6500ST to be calibrated for multiple gases while maintaining the rated accuracy on each.

    Conversion Factors
    Conversion factors for up to 256 gases are stored in the FMA6500. Conversion factors may be appliedto any of the ten gas calibrations via digital interface commands.

    Flow Alarms
    High and Low gas flow ALARM limits are programmed using the digital interface. Alarm conditions are reported via the digital interface or can activate the contact closure outputs.

    Programmable Flow
    OMEGA software supports programmable flow modes, allowing execution of custom programming of up to ten steps. Various flow configurations include ramping, linearized increasing and decreasing modes.

    Autotune
    The AUTOTUNE function allows the FMA6500 to automatically optimize control response for the gas under actual process conditions. During the AUTOTUNE process, the instrument adjusts PID gains for optimum step response and determine key control valve characteristics (only available on units with less than 80 L/min maximum flow).

    Contact Closure
    Two sets of dry contact relay outputs are provided to actuate user supplied equipment. These areprogrammable via the digital interface such that the relays can be made to switch when a specified event occurs (e.g. when a low or high flow alarm limit is exceeded or when the totalizer reaches a specified value).

    Valve Override
    Means are provided to force the control valve fully open (purge) or fully closed via either the analog or digital interfaces.

    Self Diagnostics
    Whenever power is first applied, the FMA6500 runs a series of SELF DIAGNOSTIC TESTS to ensure that it is in optimum working condition.

    Engineering Units
    The flow setpoint, measured gas flow and associated totalizer data is scaled directly in engineering units via digital interface commands. The following units of measure are supported: % of FS, mL/min, mL/hr, scfm, scfh, sL/min, sL/hr, lbs/hr, lbs/min, and one user defined unit of measure.

    Leak Integrity
    1 x 10-9 smL/sec of Helium maximumto the outside environment.

    Balanced Power Supply
    The FMA6500 operates on ±15 Vdc. The current requirements for the positive and negative powersupplies are balanced such that the current in the power supply common connection is minimized.Maximum power consumption is 13.5 watts at ±15 Vdc.

    FMA6500 Series Transducers should not be used for monitoring Oxygen gas unless specifically cleaned and prepared for such application.See ordering instructions below.

    SPECIFICATIONS
    Accuracy (including linearity): 15 to 25°C (59 to 77°F) and 0.7 to 4 bar (10 to 60 psia): ±1% of FS, 0 to 50°C (32 to 122°F) and 0.3 to 10 bar (5 to 150 psia): ±2% of FS, ±1% of FS at a specific temperature and pressure with special calibration
    Repeatability: ±0.15% FS
    Turndown Ratio: 50:1
    Response Time: 0.6 to 1.0 s to within ±2% of setpoint over 20% to 100% FS
    Temperature Coefficient: 0.05% of full scale/°C or better
    Pressure Coefficient: 0.01% FS/psi (0.07 bar) or better
    Leak Integrity: 1 x 10-9 smL/sec Helium maximum to the outside environment
    Optimum Gas Pressure: 1.73 bar (25 psig)
    Max Gas Pressure: 34.5 bar (500 psig)
    Max Diff. Pressure: 3.4 bar (50 psig) for up to 10 LPM, 2.8 bar (40 psig) for 15 LPM and greater
    Gas and Ambient Temp: 5 to 50°C (41 to 122°F)
    Output Signals: Linear 0 to 5 Vdc (2000 Ω min load impedance); 0 to 10 Vdc (4000 Ω min impedance); 4 to 20 mA optional (0 to 500 Ω loop resistance)
    Communication Interface: RS485, standard; RS232, optional
    Transducer Input Power: ±15 Vdc, 450 mA maximum
    Wetted Parts: 316 stainless steel, 416 stainless steel, FKM O-rings; Neoprene or Perfluoroelastomer O-rings optional
    Connections: Standard 1/4" compression fittings up to 30 LPM models; for 60 LPM models and greater: 3/8" compression fittings
    Circuit Protection: Circuit boards have built-in polarity reversal protection; resettable fuses provide power input protection
    Calibration Options: Standard 10-point NIST calibration optional up to 9 additional 10-point calibrations may be ordered for an additional charge



































































暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!