DPG409S Series

DPG409S Series

分  类:其它

品  牌:欧米茄

厂  商:Omega工业测量(中国)

型  号:DPG409S Series

相关行业:

发布时间:2019-12-19 17:09 浏览人数:

最新产品

产品详情
参数
包装
  • Easy to Read 25 mm (1") Backlit LCD Display
  • High 0.08% Accuracy Typical
  • Hi and Lo Alarms Standard
  • MIN/MAX/AVG Reading
  • Analog Output: User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types)
  • Data Logging and Charting Software Included
  • Wireless Transmitter Option Sends Reading to a Remote Location
  • Tested to Industrial CE Standards
  • Battery Powered with Long Battery Life
  • Analog Output Standard
  • Wireless Transmitter Optional

  • 3-A approvedOmega’s DPG409S Sanitary/CIP digital pressure gaugesincorporate a rugged 316 SSenclosure designed for washdownand marine applications with aprecision 0.08% accuracy pressuretransducer with 316L SS wettedparts and body. The result is anextremely durable digital pressuregauge designed to survive harshindustrial environments. The large25 mm (1") display is easy to readat a distance up to 11 m (35').Models are available in Gauge,Compound Gauge, Absolute,Vacuum and Barometric pressureranges. Standard features includea highly stable silicon sensor,selectable MIN/MAX and AVGreadings, Hi and LO alarms and anexternally powered user selectableanalog output. An optional wirelesstransmitter feature with softwareallows the signal to be transmittedto a remote location such as a PCfor charting and data logging. Poweris from an internal long life battery(included) or an externally supplieddc voltage source. Each unit issupplied with configuration softwarethat allows the user to connect to aPC via a standard USB connection(cable included) and select avariety of user configurable featuresincluding update rate, units,and backlight.

    SPECIFICATIONS
    RoHS Compliant
    CE Compliant: Meets industrial emissions and immunity standard IEC61326 for industrial locations
    Accuracy: ±0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined)
    Calibration: 5-Pt NIST traceable Calibration with zero and span values, Calibrated in horizontal direction (Compound Gage models calibrated in positive direction only).
    Zero Balance: ±0.5% FS typical ±1% maximum (For ranges =2.5 psi ±1%Typical ±2% maximum)
    Span Setting: ±0.5% FS typical ±1% maximum (For ranges =2.5 psi ±1%Typical ±2% maximum)
    Storage/Operating Temperature Range:
        Storage: -40 to 82°C (-40 to 180°F)
        Operating: -18 to 66°C (0 to 150°F)
    Compensated Temperature Range:
        Ranges =5 psi: 4.4 to 60°C (40 to 140°F)
        Ranges >5 psi: -4 to 85°C (25 to 150°F)
    Thermal Effect (Over Compensated Range):
    Zero and Span shift over Compensated Range
        Ranges =2.5 psi: Zero: 1.00%
        Span: 0.70%
        Range = 5 psi: Zero: 0.80%
        Span: 0.50%
        Ranges > 5 psi: Zero: 0.50%
        Span: 0.50%
    26B & 26HB Barometric Range:
        Zero: 0.90%     Span: 0.50%
    Minimum Isolation Between Case and Output Terminations:100M O @ 50 Vdc
    Analog Output: User selectable0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA(external 24 Vdc power supply requiredfor all analog output types)
    Note: Compound gage ranges have aunidirectional analog output equal to their fullspan; i.e. -15 to +15 psi = 0 to 10 Vdc.
    Analog Output Cable: 2.7 m (8.9')
    Analog Output Accuracy: 0.08% typical
    Pressure Cycles: 250,000, minimum
    Long Term Stability (1-Year): ±0.1% FS Typ.
    Fill Fluid: NEOBEE M5 Food Grade
    Approved to 3A Sanitary Specification
    Environmental Protection:NEMA 4X (IP65) depending uponelectrical termination
    Pressure Rating: 1½ and 2" Tri-GripTMFitting (compatible with Tri-Clamp®):600 psi using suitable clamp (600 psi on1½" Tri-Clamp®) only)
    Over Pressure: 4 x rated pressure tomaximum rated flange pressure
    Secondary Containment: 6 x ratedpressure to a maximum of 2000 psi (notin clamp)
    Display: 4-digit LCD with userselectable backlighting, (9999 count)25 mm (1") character height
    Computer Interface: UBS connectionfor set-up, cable included
    Sample/Display Rate: User selectablefrom 0.25 to 10 sec. (preset to 1/sec)
    Power: One 3.6V lithium 8.4 Ahcapacity (C cell) Included (Two includedwith Wireless Option)
    Battery Life (Typical): Up to 9 months
    Enclosure Material: 316 StainlessSteel and ABS center gasket
    Enclosure Finish: Brushed 316 stainless steel
    Enclosure Environmental Rating:Weatherproof, NEMA 4X (IP65)
    Connection Location: Lower (headrotates to position display)
    Front Panel Functions
    Backlight: Manually turns backlight on/off
    Min/Max: Recalls min/max values
    Zero/Clear: Zeros display or clears min/max
    Software Settings (via USB) Update Rate:4 options, 10, 5, 2, 1 times per second
    Units: psi, inHg, inH2O, bar,mbar, hPa, units must be specified at time of order
    Lock: Allows the lock-out of front panel functions
    Alarms: User selectable “High” and“Low” alarm limits. (Open Collector)
    Analog Output: User Selectable0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA(requires external 24 Vdc power)
    Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min
    Wireless Transmitter (optional):Channel Number, Transmission rate,alarms, sensor offset, chart recording, data logging
    Calibrate: Zero and Span
    Overrange Indication: “_ _ _ _”
    Wireless Option Sepcifications
    Transmit Sample Rate: Userprogrammable from 1 sample/2 min to 1 sample/2 sec
    Radio Frequency (RF) TransceiverCarrier: ISM 2.4 GHz
    RF Output: 10 dBm (10 mW)
    Range of RF Link:
        Outdoors (Line of Sight): Up to 120 m (400')
        Indoors/Urban: Up to 40 m (130')
    Included Software: Requires Windows® 7 (32 bit); XP, Vista
    Internal Battery: Two 3.6V lithium8.4 Ah capacity (C-cell) included
    Data Transmission to Host: Pressurereading, ambient temperature reading,RF transmit strength and battery level
    Dimensions:
        Display: 115 D x 89 W x 74 mm H (4.5 x 3.5 x 2.9")
        Sensor: 72 to 89 mm L (2.8 to 3.5") below display
    Weight: 900 g (2 lb) Typical depending upon configuration










暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!