DP6070 Series

DP6070 Series

分  类:测量测试仪器

品  牌:欧米茄

厂  商:Omega工业测量(中国)

型  号:DP6070 Series

相关行业:

发布时间:2019-12-19 16:47 浏览人数:

最新产品

产品详情
参数
包装
  • Modular USB, RS232, RS485 Serial Communication Options and Relays
  • J, K, T, E, R, S, B, N, C Thermocouples
  • 100 or 1000 Ù Platinum, 10 Ù Copper, 120 Ù Nickel RTDs
  • 1 or 0.1° Resolution
  • Automatic Cold Junction Compensation
  • NEMA 4X (IP65) Front
  • Universal 85 to 265 Vac or 12/24 Vdc Input Power
  • Large Dual-Line 6-Character Display, 15 and 12 mm (0.60 and 0.46")
  • Sunlight Readable Display Models
  • 2 or 4 Relays Plus Isolated 4 to 20 mA Output Options
  • External 4-Relay and Digital I/O Expansion Modules
  • Free Software for Operation, Monitoring and Programming

  • The DP6070 temperaturemeter boasts specifications andfunctionality that clearly makesit one of the most advancedtemperature meters available.It’s dual-line 6-character display,function keys, and optionalexpansion modules are only a fewof the special features available.The DP6070 accepts manythermocouple types and RTDs andcan be configured to have eithera 1° or 0.1° display resolutionon any type of sensor input. Thelower display makes configurationsimpler. The display itself is quiteconfigurable. There are manyrelay functions for up to 8 relays;including an Interlock Relayfunction. The 4 to 20 mA outputcan represent up to 12 differentparameters/variables. This makesthe DP6070 one of the mostversatile meters on the market.Sunlight readable display modelshave an extraordinarily brightLED display. The upper displaycan be programmed to indicatecurrent temperature, maximum orminimum temperature, alternatingmaximum/minimum temperatures,one of eight alarm set points, orModbus input. The lower displaycan also be configured to displayengineering units, set points,user defined legends, or simplyturned off. Input selection andconfiguration are convenientlyset up via rear switches andfront panel programming. Threelevels of password protectionhelp maintain the reliability of theprogramming.

    General Specifications
    Display: Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking
        Upper Display: 15 mm (0.60") high
        Lower Display: 12 mm (0.46") high
    Display Intensity: 8 intensity levels
    Display Update Rate: 5/second (200 ms)
    Overrange: Display flashes 999999
    Underrange: Display flashes -99999
    Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus input
    Front Panel: NEMA 4X (IP65)
    Programming Methods: 4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function
    Noise Filter: Programmable from 2 to 199 (0 will disable filter)
    Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
    Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
    Max/Min Display: Max (peak)/min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
    Password: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital inputs
    Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
    Power Options: 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W maximum, or jumper selectable 12/24 Vdc ±10%, 15 W max
    Fuse (External, Required): UL recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse,br>Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA maximum (standard), (12/24 Vdc powered models rated @ 100 mA maximum); 5 or 10 Vdc @ 50 mA maximum, selectable with internal jumper J4
    Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
    Isolation: 4 kV input/output-to-power line; 500V input-to-output or output-to-P+ supply
    Overvoltage Category: Installation overvoltage category II, local level with smaller transient overvoltages than installation overvoltage category III
    Operating Temperature Range: -40 to 65°C (-40 to 149°F)
    Storage Temperature Range: -40 to 85°C (-40 to 185°F)
    Relative Humidity: 0 to 90% non-condensing
    Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adaptors
    Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
    Mounting: 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
    Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
    Overall Dimensions: 119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64")
    Weight: 269 g (9.5 oz)


暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!