TECHNICAL DATA
Valve fitting port Ø M5 1/4"
Fluid Lubricated or unlubricated filtered air. Lubrication, if used, must be continuous.
Versions monostable guarded monostable unguarded Monostabile - bistable guarded
Operating pressure 2.5 ÷ 10 bar - 0.25 ÷ 1 MPa - 36 ÷ 145 psi
Temperature range -10°C + 60°C
Nominal diameter 2.5 mm 2.5 mm 7.5 mm
Conductance C 16.5 Nl/min 16.5 Nl/min 264.26 Nl/min
Critical ratio b 0.03 bar/bar 0.03 bar/bar 0.32 bar/bar
Flow rate at 6.3 bar P 0.5 bar 60 Nl/min 60 Nl/min 640 Nl/min
Flow rate at 6.3 bar P 1 bar 95 Nl/min 95 Nl/min 840 Nl/min
[img]20054261864511028.jpg[/img][img]2005426187032490.jpg[/img]